- CHANGING HP SMART ARRAY CONTROLLER IN EXISTING SERVER INSTALL
- CHANGING HP SMART ARRAY CONTROLLER IN EXISTING SERVER UPDATE
CHANGING HP SMART ARRAY CONTROLLER IN EXISTING SERVER UPDATE
Supplemental Update / Online ROM Flash Component for Linux (圆4) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822 (8.32), searching.ġ) Smart Array P420i Smart Array P420i in Slot 0 (8.00) A quick search online revlealed a much newer firmware was available for the controller on the hpe website.Īfter downloading and extracting the latest firmware ( 8.32 as of this writing) I flashed it to the controller following the instructions provided by HPE with the firmware. When I looked at the firmware I noticed was version 8.00. However I thought I would try some troubleshooting before ordering replacements online. I can imagine a scenario where a supercap has failed, I recently had to replace a pair of them on my Liftmaster garage door opener. The following screenshots start with a controller in hardware mode in (HPE terms Smart Array Mode), then enable the HBA mode, the OS will see the disks as JBOD and then again enable the hardware mode (Smart Array Mode): SCREENSHOT 1) Click on the controller Smart Array P440 on the left and then Enable HBA Mode to enable JBOD mode. WARNING: Before you proceed enabling Smart Array S100i SR is NOT CURRENTLY SUPPORTED in VMware, (you wont even see a storage controller if you carry out the following procedure. The posted write cache has been disabled because the backup power source attached to the flash-backed write cache module has failed to charge. The client wanted them changing to RAID1 (fair enough) so I revisited the drive setup. When I logged into the host and ran the ssacli utility I got some more detail on the problem.Ĭache Status Details: Cache disabled backup power source failed to charge to an acceptable levelĬache Disable Reason: Permanent disable condition. Caching will be enabled once Super-Cap has been replaced and charged. Server-class technology allows for 24x7 business operations, offering higher reliability and longer lifecycle. POST Error: 1705-Slot X Drive Array - Please replace Cache Module Super-Cap. HP Dynamic Smart Array B120i Controller provides an embedded 6 Gbps SATA controller RAID solution for customers who use SATA drives for both boot and data to protect critical data from loss of a disk drive.
CHANGING HP SMART ARRAY CONTROLLER IN EXISTING SERVER INSTALL
At the iLO main menu, the options are to either Configure and Install which provides a wizard to perform a clean install and system reset to defaults or Perform Maintenance, where you can delete or add drives on existing RAID disks. Choose Exit and Launch HP Storage Administrator. I checked the ILO management interface and noticed that the Smart Array controller was reporting the following error in the IML log: Chose Embedded RAID 1: Smart Array P440ar controller. Recently one of them had an amber indicator light illuminated. They’re older and out of support but they work just fine for my lab testing. I have a few HPE D元60P Gen8 servers in my home lab for testing and learning purposes.